Government Contract | Kentucky
RFB-127-22 RAD Tech Renovation Jolly Classroom Hazard

Bid Information


Bid Alert No: 00002890982

Bid Title: RFB-127-22 RAD Tech Renovation Jolly Classroom Hazard

Agency Bid No. Title: RFB-785-2200000401

Received Date: 01/24/2022

Close Date: 02/23/2022

Purchase Type: Not Stated

Delivery Point: Hazard Community College, J.Marvin Jolly Classroom Center, 1 Community College Drive, Hazard, Kentucky, 41701

Delivery Date: Not Stated

Special Notices: Site-Walk 01/27/2022 10:30 AM, Pre-Bid Conference 02/02/2022 11:00 AM, Bidder Preregistration

Specifications

Specifications include, but are not limited to: ARCHITECTURALThe Hazard Community and Technical College (HCTC) Rad-Tech renovation project primarily consists of the approximately 400 square feet selectivedemolition and renovation of existing shell space on the first floor of the J. Marvin Jolly Classroom Center in Hazard, Kentucky into a Radiology TrainingLab and Control/Observation Room. The build-out of the new Radiology Training Lab includes the installation of a new X-Ray, lining of the room withlead-lined gypsum board, a new lead-lined door, lead protective viewing window, resilient flooring, acoustical tile ceiling and storage cabinets. TheControl / Observation Room receives a new solid core wood veneer door to match existing along the corridor, built-in workstation, resilient flooring, andacoustical tile ceiling.This project includes providing HVAC and electrical systems to accommodate the new Rad-Tech Lab area in the Jolly Classroom Building.;STRUCTURALThe structural scope of the project consists of supporting the new X-ray equipment. The equipment is being supported by a system of unistruts which arethen supported by (2) structural steel beams. These beams are being hung from the existing structural steel beams with hollow structural steel posts andbraced with unistruts to prevent sidesway. The X-ray equipment has a very stringent deflection criteria which is unrealistic to meet without providingcompletely new structural support systems. It was decided that the existing support system would be sufficient to support the hanging mechanism. Theprimary support system as shown will provide the deflection criteria as required; however, the existing building which ultimately supports the X-rayequipment does not. ;HVACA new VAV box with hot water re-heat will serve the X-Ray room. It will tie into the existing supply air duct and the existing boiler hot water loop.The Control Room will be served by the existing VAV box. Ductwork will be added/modified to accommodate this area.;ELECTRICALNew lighting and power to room fit up. Electrical connections to X-ray equipment.

Product Codes: 91017, 90922, 91450, 91065

Agency Information


Issuing Agency: Commonwealth of Kentucky - Department of Facilities & Support Services

State: Kentucky

Agency Type: State and Local

Contact: Susan Ward 403 Wapping Street, 1st Floor, Frankfort, Kentucky, 40601

Phone: 502-564-3050

Email: susan.ward@ky.gov

< PREVIOUS PAGE

GET A FREE
MARKET
ANALYSIS

FREE Market Analysis


Get a FREE 90-Day Market Analysis and see the bids you’ve been missing

GET BIDS NOW