Government Contract | Illinois
Ozone Monitors

Bid Information


Bid Alert No: 00002657404

Bid Title: Ozone Monitors

Agency Bid No. Title: 22-532EPA-FISCP-B-22715

Received Date: 06/21/2021

Close Date: 07/07/2021

Purchase Type: Term:

Delivery Point: Not Stated, Illinois

Delivery Date: Not Stated

Specifications

Specifications include, but are not limited to: Monitor must have a voltage rating of 120 VAC at 60 HZ.Monitor must have handle(s) or come with a carrying case with handles.Monitor must have a selectable ozone range with at least a 200 ppb option.Monitor must have a dynamic Zero on or off option when performing nightly zero checks, i.e., the option to automatically reset the monitor zero value when performing nightly zero checks.Monitor must be temperature and pressure compensated.Monitor must have an internal long-life sample line filter designated as lasting a minimum of one year, and filter must be approved for use as part of the monitors USEPA Equivalency approval.Monitor must have zero and span valves available for conducting nightly zero and span checks (with an Agency-supplied external ozone transfer standard) by switching the monitor from sampling mode to verification mode that activates the zero and span valves. The monitor software needs to be capable of changing monitor operations such that those operations can be initialized by the site data logger.Monitor must have a zero scrubber for nightly zero checks that is separate from the zero and span valves and the zero references the monitor utilized during sampling. The zero scrubber for nightly zero checks and the valves and scrubbers of 1.2.1.8 must be accessible and able to be utilized simultaneously..Monitor must have an ethernet communication port.Monitor must have Modbus Protocol communication via ethernet on port 502 for logging and storing ozone data and ozone diagnostic parameters andfor the logger controlling and initializing the monitor sampling mode, monitor verification mode, monitor zero ports, monitor span ports and monitor calibration functions.Monitor must be fully compatible with Agilaire and ESC Data Loggers for Modbus communication and control and must be backwards compatible with Agilaire 8872 and ESC 8832 Data Loggers.Monitor must have an internal sample pump.Monitor must have remote login capable Windows-Based software with data retrieval with a minimum of ten (10) licenses.Monitor must have a digital I/O expansion board.Monitor must have at least one (1) USB port.Monitor must be rack mountable.Monitor must come with two (2) years of expendables, i.e. all components that are required to be changed on an annual basis or on a shorter timeframe.Monitor must have a two (2) year parts and labor warranty.

Product Code: 89049

Agency Information


Issuing Agency: State of Illinois - Illinois Environmental Protection Agency (Illinois EPA)

State: Illinois

Agency Type: State and Local

Contact: Elizabeth Helton

Phone: 217-782-9892

Email: elizabeth.helton@illinois.gov

< PREVIOUS PAGE

GET A FREE
MARKET
ANALYSIS

FREE Market Analysis


Get a FREE 90-Day Market Analysis and see the bids you’ve been missing

GET BIDS NOW