Bid Information


Bid Alert No: 00002445001

Bid Title: Municipal Pier Utility Tray Repairs RE-BID

Agency Bid No. Title: 012-21

Received Date: 12/22/2020

Close Date: 12/29/2020

Purchase Type: 30 calendar days

Delivery Point: Fairhope, Alabama

Delivery Date: Not Stated

Specifications

Specifications include, but are not limited to: a. Hanger Rod Enduro DuroThread TR-FRP-0625 or equivalentb. Double Nuts - Enduro DuroThread FN-FRP-0625 or equivalentc. Flat Washers - Enduro DuroThread FW-FRP-0625 or equivalentd. Lower Strut UNISTRUT P100HS - Stainless Steel, Type 304 (SS): ASTM A240, Type304 or equivalente. Lower Utility Tray Enduro 18 ELL4 or equivalent no coverf. Upper Utility Tray match existing Enduo with cover Enduro EPC or equivalentg. All other hardware shall be a strong non-metallic mechanical fastener with requisite shearand tensile strength, or 304 Stainless Steel or better.i. Electric 7200 Volt Primary Continuous red conduit from shore to transformer(supplied by electric department), no elbows or other fittings (elbows, 45s, other than couplings at the shore and at the transformer). Once conduit is installed,the electric department will pull and terminate cable. Transformer will not beenergized until secondary work to the panels is completed and inspected by thebuilding department to ensure safety.ii. All Secondary work by licensed electricians and approved by building departmentprior to energization, including new PVC conduit and copper to re-establish earthground at the shoreb. Wateri. Water line should be 2 (IPS) HDPE (ANSI/NSF 61/14, ANSI/AWWA C901/C906)DR 11 Pressure Class 200 with blue stripe running entire length of pipe. Pipeshall be one continuous length joined by thermal butt-fusion. No mechanicalcouplings installed. Fused fittings only. Fusion machine and fusion machineoperator shall be approved by pipe manufacturer. Restrained by corrosionresistant hardware spaced according to engineer/owner recommendations.c. Seweri. Low pressure sewer line should be 3 (IPS) HDPE (ANSI/NSF 61/14,ANSI/AWWA C901/C906) DR 11 Pressure Class 200 with green stripe runningentire length of pipe. Pipe shall be one continuous length joined by thermal buttfusion. No mechanical couplings installed. Fused fittings only. Fusion machineand fusion machine operator shall be approved by pipe manufacturer. Restrainedby corrosion resistant hardware spaced according to engineer/ownerrecommendationsd. Gasi. Reestablish a PE gas service that feeds the restaurant only.ii. PE gas service shall be placed in 2 diameter schedule 40 PVC conduit(casing). The conduit (casing) shall have Natural Gas labels along the length ofthe service.iii. Run is from the start of the Pier (In the approximate area of the electrictransformer) at the location of the gas service shut off valve.iv. Service runs from this valve thru the sea wall and into the 2 PVC conduit(casing) to the restaurant at that location is an anode less riser that extends outof the PVC conduit (casing) and ties into the meter set.e. Telecommunicationsi. Coordinate with each applicable service provider

Bid Related Documents

Download Document

Product Codes: 57068, 91438, 91458

Agency Information


Issuing Agency: City of Fairhope

State: Alabama

Agency Type: State and Local

Contact: 555 South Section Street, Fairhope, Alabama, 36532

< PREVIOUS PAGE

GET A FREE
MARKET
ANALYSIS

FREE Market Analysis


Get a FREE 90-Day Market Analysis and see the bids you’ve been missing

GET BIDS NOW