Specifications

Specifications include, but are not limited to: maintenance">1,300 lb. lift capacity.maintenance">Minimum 12-gauge steel platform.maintenance">50 platform travel.maintenance">Approximate platform dimensions: 76 x 34. Platforms shall have an open diamond pattern on a steel-grating to allow air flow and grip-style surface.maintenance">Must fit 84 wide flatbed to outside of rub rail.maintenance">Electric Control with:maintenance"/>maintenance">Toggle switch control.maintenance">90-second automatic delay shut-off after last operation to help prevent unauthorized use.maintenance">Low voltage protection device.maintenance">Heat shrink electrical connections.maintenance">Reset button permanently mounted on the lift gate.maintenance">150-amp circuit breaker with manual reset.maintenance">Factory supplied power cable molded with ground cable.maintenance">Built-in relief valve.maintenance">Di-chromate plated arm pins.maintenance">Hydraulic flow control valve guards against uncontrolled descent of platform in the event of hydraulic hose failure.maintenance">Frame Works, pump, cylinder, and electrical components are inside the gate framework.maintenance">Main frame box cover, removable with lift in raised or lowered position to provide for easier servicing.maintenance">Platform torsion assist spring to provide easier closure.maintenance">Dual latching system to insure positive platform closure.maintenance">GROUP 2 LOW PROFILE LIFT GATE SPECIFICATIONSmaintenance">1,300 lb. lift capacity.maintenance">Minimum 12-gauge steel platform.maintenance">50 platform travel.maintenance">Approximate low profile platform dimensions: 76 x 20. Platforms shall have an open diamond pattern on a steel-grating to allow air flow and grip-style surface.maintenance">Must fit 84 wide flatbed to outside of rub rail.maintenance">Electric Control with:maintenance"/>maintenance">Toggle switch control.maintenance">90-second automatic delay shut-off after last operation to help prevent unauthorized use.maintenance">Low voltage protection device.maintenance">Heat shrink electrical connections.maintenance">Reset button permanently mounted on the lift gate.maintenance">150-amp circuit breaker with manual reset.maintenance">Factory supplied power cable molded with ground cable.maintenance">Built-in relief valve.maintenance">Di-chromate plated arm pins.maintenance">Hydraulic flow control valve guards against uncontrolled descent of platform in the event of hydraulic hose failure.maintenance">Frame Works, pump, cylinder, and electrical components are inside the gate framework.maintenance">Main frame box cover, removable with lift in raised or lowered position to provide for easier servicing.maintenance">Platform torsion assist spring to provide easier closure.maintenance">Dual latching system to insure positive platform closure.maintenance">GROUP 3 LIFT GATE SPECIFICATIONSmaintenance">1,300 lb. lift capacity.maintenance">Minimum 12-gauge steel platform.maintenance">50 platform travel.maintenance">Approximate platform dimensions: 86 x 36. Platforms shall have an open diamond pattern on a steel-grating to allow air flow and grip-style surface.maintenance">Must fit 96 wide flatbed to outside of rub rail.maintenance">Electric Control with:maintenance"/>maintenance">Toggle switch control.maintenance">90-second automatic delay shut-off after last operation to help prevent unauthorized use.maintenance">Low voltage protection device.maintenance">Heat shrink electrical connections.maintenance">Reset button permanently mounted on the lift gate.maintenance">150-amp circuit breaker with manual reset.maintenance">Factory supplied power cable molded with ground cable.maintenance">Built-in relief valve.maintenance">Di-chromate plated arm pins.maintenance">Hydraulic flow control valve guards against uncontrolled descent of platform in the event of hydraulic hose failure.maintenance">Frame Works, pump, cylinder, and electrical components are inside the gate framework.maintenance">Main frame box cover, removable with lift in raised or lowered position to provide for easier servicing.maintenance">Platform torsions assist spring to provide easier closure.maintenance">Dual latching system to insure positive platform closure.

Bid Related Documents

Download Document

Bid Related Attachments

Download Attachment

Product Codes: 05590, 54539, 56049

Agency Information


Issuing Agency: State of Montana - Department of Transportation (MDT)

State: Montana

Agency Type: State and Local

Contact: Richele Parkhurst, Purchasing Services Section

Phone: 406-657-0274

Fax: 406-256-6487

Email: rparkhurst@mt.gov

< PREVIOUS PAGE

GET A FREE
MARKET
ANALYSIS

FREE Market Analysis


Get a FREE 90-Day Market Analysis and see the bids you’ve been missing

GET BIDS NOW