Government Contract | District of Columbia
ANNUAL FIRE EXTINGUISHER INSPECTION & MAINTENANCE SERVICES/EQUIPMENT

Find Open Contracts in the Architecture and Engineering Industry

Find Contracts Now

Bid Information


Bid Alert No: 00002759407

Bid Title: ANNUAL FIRE EXTINGUISHER INSPECTION & MAINTENANCE SERVICES/EQUIPMENT

Agency Bid No. Title: 21-S-014-711

Received Date: 09/22/2021

Close Date: 09/27/2021

Purchase Type: Not Stated

Delivery Point: Washington, District of Columbia

Delivery Date: Not Stated

Special Notices: Questions Due By 09/22/2021 05:00 PM

Specifications

Specifications include, but are not limited to: (a) The Contractor shall provide inspection and maintenance services to Events DCs fire extinguishers. Theservices may be required to be performed at the Walter E. Washington Convention Center or any other EventsDC Facilities.(b) The Contractor shall conduct all Work under the direction of Events DCs designated on-site representative,the Contracting Officers Technical Representative (COTR). Contact information for the COTR will beprovided at the time of Contract award.(c) All Work shall be done in compliance with District of Columbias Fire CodeC.2 INSPECTION SERVICES(a) To be considered for award the Contractor shall:i. Check that a portable fire extinguisher exists within a 30-foot travel distance ofcommercial-type cooking equipment that uses cooking oil or animal fat.ii. Check that a portable fire extinguisher is within 75-feet of travel on every floor.iii. Check for the presence of portable extinguishers and determine that they are located in conspicuousand readily available locations immediately available for use, and not obstructed or obscured fromview.iv. Confirm that access to extinguishers is not obstructed.v. Make sure that the hose (if so equipped) is intact and not obstructed.vi. Make sure the pressure dial reads in the green or "charged" area. It should also be clear and readable.vii. Check that the pull pin is securely fastened within the handle and held in place by the tamper seal.viii. Check for visible dents or cracks in the extinguisher body.ix. Check that the extinguisher is in its proper location and mounted correctly.

Product Code: 93634

Agency Information


Issuing Agency: Events DC

State: District of Columbia

Agency Type: State and Local

Contact: Ishmael Murray

Phone: 202-322-9477

Email: imurray@eventsdc.com

< PREVIOUS PAGE

GET A FREE
MARKET
ANALYSIS

FREE Market Analysis


Get a FREE 90-Day Market Analysis and see the bids you’ve been missing

GET BIDS NOW