Government Contract | Florida
Roof Replacement of Staff Housing at Reception and Medical Center

Bid Information

Bid Alert No: 00000459555

Bid Title: Roof Replacement of Staff Housing at Reception and Medical Center

Agency Bid No. Title: FDC ITB-15-104

Received Date: 01/13/2016

Close Date: 02/09/2016

Purchase Type: 90 Days

Delivery Point: 7765 South CR 231, Lake Butler, Florida, 32054

Delivery Date: Not Stated

Special Notices: Pre-Bid Conference Mandatory 01/20/2016 02:00 PM, Questions Due By 01/22/2016 05:00 PM


Specifications include, but are not limited to:SHINGLESSelf sealing, granule surfaced, asphalt shingle with a strong fiberglass reinforced Micro Weave core andStainGuard protection, which prevents pronounced discoloration from blue-green algae throughformulation/unique blends of granules. Architectural laminate styling provides a wood shake appearancewith a 5 5/8 inch exposure. UL 790 Class A rated with UL 997 Wind Resistance Label; ASTM D 7158, Page 29 of 37 FDC ITB-15-104Class H; ASTM D 3161, Type 1; ASTM D 3018, Type 1; ASTM D 3462; AC438; CSA A123.5-98; DadeCounty Approved, Florida Building Code Approved ICC Report Approval. Timberline HD Lifetime HighDefinition Shingles, by GAF.2.03 HIP AND RIDGE SHINGLESHigh profile self sealing hip and ridge cap shingle matching the color of selected roof shingle. Each bundlecovers approx. 20 lineal feet (6.10m). Timbertex Premium Ridge Cap Shingles, by GAF.2.04 STARTER STRIPSelf sealing starter shingle designed for all roof shingles. Each bundle covers approx. 120 lineal feet(36.58m). ProStart Starter Strip by GAF.2.05 LEAK BARRIERSelf-adhering, self sealing, bituminous leak barrier surfaced with a smooth polyethylene film. Approved byUL, Dade County, ICC,and the State of Florida and Texas Department of Insurance. Each Roll containsapprox. 200 sq ft. (18.6 sq.m.), 36 X 66.7 (0.9m x 20.3m), and 60 mils thick. StormGuard Leak Barrier, byGAF.2.06 SHINGLE UNDERLAYMENTSuperior quality, water repellant, non-asphaltic underlayment. UV stabilized polypropylene construction.Meets or exceeds ASTM D226 and D4869. Each roll contains approximately 10 squares (1003 sq. ft.) ofmaterial and is 54 x 223. TigerPaw Roof Deck Protection, by GAF.2.07 ROOFING CEMENTA. Asphalt Plastic Roofing Cement meeting the requirements of ASTM D 4586, Type I or II.B. Roof Cement: ASTM D 4586, Matrix203 Plastic Roof Cement.C. Roof Cement: ASTM D 4586. Matrix 204 Wet/Dry Roof Cement.2.08 ROOF ACCESSORIESExterior acrylic rust resistant aerosol roof accessory paint. Each 6 oz can is available in boxes of 6 and in awide variety of colors to compliment the roof. Shingle-Match Roof Accessory Paint by GAF2.09 ATTIC VENTILATIONRidge VentsRigid plastic ridge ventilator designed to allow the passage of hot air out of attics. For use in conjunctionwith eave/ soffit intake ventilation products. Provides 18.0 sq inches (11613 in NFVA per linealfoot. Each package contains 40 lineal feet (12.19m) of vent. Cobra Rigid Vent 3 ridge vent (includes 3(76mm) galvanized ring shank nails), by GAF2.10 NAILSStandard round wire, zinc-coated steel or aluminum; 10 to 12 gauge, smooth, barbed or deformed shank,with heads 3/8 inch (9mm) to 7/16 inch (11mm) in diameter. Length must be sufficient to penetrate into solidwood at least 3/4 inch (19mm) or through plywood or oriented strand board by at least 1/8 inch (3.18mm).2.11 METAL FLASHINGA. 24 gauge hot-dip galvanized steel sheet, complying with ASTM A 653/A 653M, G90/Z275.B. 16-oz/sq ft (0.56mm) copper sheet, complying with ASTM B 370.C. 0.032-inch (0.8mm) aluminum sheet, complying with ASTM B 209.PART III EXECUTION3.01 EXAMINATIONA. Do not begin installation until the roof deck has been properly prepared.B. If roof deck preparation is the responsibility of another installer, notify the architect or buildingowner of unsatisfactory preparation before proceeding.3.02 PREPARATIONA. Clean deck surfaces thoroughly prior to installation of eaves protection membrane andunderlayment.B. At areas that receive eaves protection membrane, fill knotholes and cracks with latex filler.C. Install crickets on the upslope side of all chimneys in the north, any chimney wider than 24(610mm), and on all roofs steeper than 6/12.D. Replace any defective decking to match existing and nail off per applicable code.3.03 INSTALLATION OF UNDERLAYMENTSA. General1.Install using methods recommended by the manufacturer, in accordance with localbuilding codes.2. When local codes and application instructions are in conflict, the more stringentrequirements shall take precedence.B. Eaves1. Install eaves edge metal flashing tight with fascia boards; lap joints 2 inches (51mm) andseal with plastic cement or high quality urethane sealant; nail at the top of the flange.

Product Code: 91473

Agency Information

Issuing Agency: State of Florida - Department of Corrections

State: Florida

Agency Type: State and Local

Contact: Jacklyn Colson 501 S. Calhoun Street, Tallahassee, Florida, 32399

Phone: 850-717-3688

Fax: 850-488-7189




FREE Market Analysis

Get a FREE 90-Day Market Analysis and see the bids you’ve been missing