Government Contract | Kansas
Pole Light Replacement Boston Recreation Center

Bid Information

Bid Alert No: 00000430825

Bid Title: Pole Light Replacement Boston Recreation Center

Agency Bid No. Title: FB540234

Received Date: 12/03/2015

Close Date: 12/11/2015

Purchase Type: Not Stated

Delivery Point: Wichita, Kansas

Delivery Date: Not Stated

Special Notices: Bid Bond Required: , Performance Bond Required: , Payment Bond Required:


Specifications include, but are not limited to:1. Install new PVC conduit (1" minimum) thru-out. Galvanized Rigid Conduit to be used for 90s and risers. This includes exposed home run conduits and LBs entering a structure or building. 2. Provide one empty spare stub out one foot beyond base and cap toward open area at each pole 3. The City will select six ofthe existing poles and fixtures to reuse at other facilities. The Electrical Contractor will then be responsible for removing and disposing the remainder of the old poles, fixtures and all of the concrete bases. 4. The Electrical Contractor will backfill excavations and reseed grass appropriately. 5. Directional Boring shall be utilized when in the drip zone of existing trees or for parking lot lights. Trenching only allowed in open grass areas with no trees. 6. The Electrical Contractor will provide the correct Concrete Pole Bases for the specified poles and fixtures. It will also be the Electrical Contractors responsibility to include detail drawings verified and sealed by a State of Kansas Structural Engineer as required by MABCD. Parking Lot bases to be a minimum of 2' above grade with chamfered edge. Pathway lights to be a minimum of 6" above grade with chamfered edge. 7. Pole placement is to be as near as possible to the photometric design provided by Premier Lighting and Controls.(24"x36" color drawing posted online 8. Poles and fixtures are to be black in color. 9. All specified materials are to be as specified or approved equal. Any alternate parts would require complete performance data and point to point design. 10. Quantity (S)-label S5 Cree ARE-EDG-SM-DM-16-E-UL-BK-S2S-S7K (S2SMa) fixtures for parking lots. Poles for these are to be: General Structures CPS-1-4011-2S-D1-CTBL 11. Quantity (3)-label PT2 Cree ARE-EDR-2M-PT-OG-E-UL-BK-S2S-S7K (S2SmA) fixtures for sidewalks. Poles for these are to be: General Structures CPS-4-4011-16-T2-CTBL 12. Quantity (7)-label PT5 Cree ARE-EDR-SM-PT-OG-E-UL-BK-S2S-S7K (S2SmA) fixtures for sidewalks. Poles for these are to be: General Structures CPS-4-4011-1G-T2-CTBL 13. Existing lighting controls and breakers can be utilized. Recreation Center Parking Lot Lights are computer controlled with a Hand-off-Auto selector switch. This can remain the same. If the Home Run conduit is in good condition it can be tied onto as close to the building as possible and reused. Otherwise all the rest of the conduit should be new. The West Parking Lot and the

Product Code: 91438

Agency Information

Issuing Agency: City of Wichita

State: Kansas

Agency Type: State and Local

Contact: Clarence Rose 455 N. Main, 12th Floor, Wichita, Kansas, 67202

Phone: 316-268-4414

Fax: 316-268-4656