Government Contract | Kentucky
Mobile Equipment Containment

Bid Information

Bid Alert No: 00000537669

Bid Title: Mobile Equipment Containment

Agency Bid No. Title: 1600000762

Received Date: 04/08/2016

Close Date: 04/21/2016

Purchase Type: completion by 6/30/16

Delivery Point: 200 Fair Oaks Lane, Frankfort, Kentucky, 40601

Delivery Date: Not Stated


Specifications include, but are not limited to:. Extended Description SHELTER ONE # E0810812 Model E Shelter, CONSOLIDATED ANALYTICAL SYSTEMS No. 9001-10-8 or approved Equal Mobile Air Quality Monitoring Equipment Shelter Shelter must comply with all Local, State and Federal requirements including 2013 Kentucky Building Code requirements. Shelter Features must include: Approximate Dimensions: 8W (OD) X 10L (OD) X 8H (ID) Approximate. 3x2 Aluminum Skid runners (2) design that will fit EKTO twin axle transport trailer Model #1641-TR2 Side wall brackets that will work with standard EKTO shelter lifting jacks. (Jacks not required) 24ga Pre-finished Steel Exterior Cladding with Aluminum Trim Fiberglass Reinforced interior cladding. Commercial grade tile or vinyl flooring Rubber or PVC type Membrane roof, slip resistant. Roof exterior shall be designed to mount equipment & support personnel. insulation in walls, ceiling and floor, must meet or exceed 2013 Kentucky Building Code requirements. Insulated metal access door, 36"W includes: Hydraulic door closer, weather stripping, door drip, door threshold, commercial type handle with lock. Vertical ladder with gate, allows roof access mounted on Shelter. Aluminum roof area railing system. System to be removable for ease of transport. Must meet OSHA specifications. Tie down rings required in all four corners. 8 foot X 30 inch deep work bench. Electrical System: Meets or exceeds NEC regulations 200A Electrical System, 120/240V. All circuits to be protected by circuit breakers. In addition to the HVAC power requirements, there shall be a minimum or nine (9) duplex outlets on the shelter interior, minimum one (1) exterior gad GFI outlet mounted for easy access from roof. Shelter main power entrance shall be via Meter Socket and Mast. Minimum two 48x2 bulb fluorescent light fixtures mounted to the ceiling. Environment Control: The shelter interior must be temperature controlled (75 degrees Fahrenheit +/- degrees Fahrenheit) at exterior temperatures of -30 degrees Fahrenheit to 100 degrees Fahrenheit, by use of a Bard WA Series or approved equivalent brand Wall-mount type air conditioner/heater combo.24000 BTU A/C with 5000 BTU Heat. Green Refrigerant R-410A - Non ozone depleting. Unit price is to include Shipping and Handling to the Kentucky Division for Air Quality's office at 200 Fair Oaks Lane, Frankfort, Kentucky 40601. FOB Destination The Highest Evaluated bidder will be required to submit Shop Drawings within 14 calendar days notice. Drawings are not required with RFB response. The Highest Evaluated bidder may also be required to provide visual examples of similar shelters and or references. Delivery required to be completed no later than JUNE 30th, 2016. SEE SECTION 16 METHOD OF AWARD Vendor is required to offload shelter and set in place when delivered

Bid Related Documents

Download Document

Bid Related Attachments

Download Attachment Download Attachment

Product Code: 15580

Agency Information

Issuing Agency: Commonwealth of Kentucky - Office of the Controller

State: Kentucky

Agency Type: State and Local

Contact: Richard Mize, Finance and Administration Cabinet Office of Procurement Services, Capitol Annex, 702 Capitol Ave, Room 095, Frankfort, Kentucky, 40601

Phone: 502-564-4510

Fax: 502-564-1434




FREE Market Analysis

Get a FREE 90-Day Market Analysis and see the bids you’ve been missing