Bid Title: Medical Equipment - Wheelchair lift

Agency Bid No. Title: RFB-IS-16201673

Received Date: 05/30/2016

Close Date: 06/08/2016

Purchase Type: Not Stated

Delivery Point:

Delivery Date: Not Stated

Special Notices: Bidder Preregistration


Specifications include, but are not limited to:The product described herein, manufactured by Ascension, is a portable lifting device intended for use by individuals with disabilities. The lift shall consist of a platform supported on electro-hydraulic lifting mechanism with built-in caster for portability. The casters shall permit easy movement of the unoccupied lift over hard, level surfaces. With the casters removed, the lift shall rest firmly on any hard, level surface, and provide a stable base for operation of the lift. The lift shall be low profile (no machine tower) to maintain viewing lines. The lift shall provide for independent use by individuals with disabilities and include all operating and safety devices for compliance with ADA requirements as applicable to portable lifts. The lift shall have a slim profile platform frame to eliminate the need for a pit or access ramp on the landing side and facilitate easy entry into the lift directly at floor level by Patrons.PRODUCT COMPLIANCE:For the item identified above and below by product name any product equal in quality and appearance as well as identical in function to that specified maybe offered as an alternate. QUALITY ASSURANCE: Manufacturer shall have not less than ten (10) years of experience in the design and manufacture of vertical wheelchair lifts. ASCENSION WHEEL CHAIR LIFT:A fully assembly, safe manually portable vertical wheelchair lift to transfer ADA patrons on stage. This wheelchair lift needs to have low profile stance in the down position not to exceed 44 to 49 inches in height.Fully enclosed transparent sidewall construction.oReassures children and encourages faculty to monitor activity in the lift at a glance.Quiet electro-hydraulic operation.Lift has to access at least a minimum height of 42 to height of stage. Automatic dock plate.Compression CapabilityReduces the width of the lift for transport through narrow doorways (34-48).Safety features:oFully ADA compliant as applicable to portable lifts.o24VDC operating controls. oUnder-platform safety pan.oElectro-mechanical interlock to prevent accidental opening of lower landing platform gate. oGround Fault circuit Interrupter (GFCI), oGate switches to prevent platform movement if either platform gate is open. oFull-height sides all the way around safeguard wheelchair attendants and other standing patrons.oGrab bars extending full length of inside wall.oSlip-resistant surfaces. oPower-out hydraulic hand pump. oSelf-closing platform gates.oPush to Stop emergency buttons.PORTABILITY:Casters shall be easily attached to the platform for portability and storage when not in use. Casters shall be 5 in diameter and capable of being installed without tools.The lift shall also be capable of being moved by forklift or truckOPERATING CHARACTERISTICS:The lift shall include three (3) constant pressure UP/DOWN switches, located outside of the platform at both ends and inside the platform. The passenger control station shall be provided with a separate PUSH TO STOP emergency button. The platform stop height shall bel adjustable without the use of tools. Opening the upper landing platform gate shall deploy a dock plate that rests on the upper landing surface. The late shall provide a smooth transition between the platform and the upper landing. Closing the upper landing platform gate shall retract the dock plate.The lower landing platform gate shall be provided with a mechanical interlock that prevents the platform gate from being opened whenever the platform is more than 2 above the full down position. COMPRESSION CAPABILITY:The lift shall be capable of being compressed to 33 wide to facilitate relocation through a 36 wide doorway. ELECTRICAL REQUIREMENTS:A.Electrical power requirements shall be compatible with 120VAC, 60 hertz, single phase, 15 amp service.B.Lift shall be supplied with a three prong ground electrical cord. C.Motor shall be at least hp, 115V AC single phase. D.The lift shall contain a Ground Fault Circuit Interrupter (GFCI).FINISH:All metal components shall be thoroughly cleaned to remove any foreign substance. Exposed metal surfaces shall be finished with an oven-bake powder coating. Exposed base frame metal surfaces shall be hot-dip galvanized. Standard color is black. WARRANTY:Manufacturer shall provide a twenty (20) year warranty on pumps, motors, and hydraulic cylinders (drive train), five (5) year all other parts, one (1) year labor warranty.

Bid Related Documents

Download Document

Bid Related Attachments

Download Attachment

Product Code: 47081

Agency Information

Issuing Agency: County of Los Angeles

State: California

Agency Type: State and Local

Contact: Li Zhu, Internal Services Department ISD Central Purchasing, 1100 N. Eastern Ave. Room 103, Los Angeles, California, 90063