LEASE FOR ARROWHEAD REGIONAL MEDICAL CENTER (ARMC)

Bid Information


Bid Alert No: 00000502981

Bid Title: LEASE FOR ARROWHEAD REGIONAL MEDICAL CENTER (ARMC)

Agency Bid No. Title: RESD116-RES-1813

Received Date: 03/08/2016

Close Date: 05/03/2016

Purchase Type: 10 years for completion

Delivery Point:

Delivery Date: Not Stated

Specifications

Specifications include, but are not limited to:CEILINGS:a. 2' x 4' suspended acoustic ceiling with DonnDX exposed ceiling tile tee systems, white. Fire rated system in areas required by Code. b. Ceilings are to be nine foot (9'), unless otherwise specified. c. Three-fourths inch (3/4) thick Armstrong #1811 Fine Fissured High NCR acoustical ceiling panels, (AP-1), NRC range 0.70, color - white, when specified in Finish Specifications. 1.2 LIGHTING:a. 2' x 4' three (3), or four (4) tube fluorescent drop-in fixtures or as allowed by current Energy Codes. Lighting must meet all Uniform Building Codes applicable to commercial office buildings. All rooms to have separate lighting controls (switches or light sensors). b. Each fluorescent light fixture shall be identified; with black permanent pen or equivalent, as to which circuit and electrical sub panel it receives power. Marking must be done in such a way as to be easily seen when cover is removed, but not seen with cover on. c. Lighting fixtures must run parallel of work surfaces, or shelving units in storage rooms. All reflected ceiling plans (light fixture locations) must be reviewed and coordinated with the modular furniture vendor and approved by the COUNTY. d. Night light fluorescent fixtures are to remain on at all times in each lobby, open area, and inside employee entrance door. e. Energy efficient emergency exit signs must be provided as per local building code. Provide additional emergency lighting for all restrooms and exit passages per local code approval. If fluorescent light fixtures are utilized for emergency battery back-up lighting purposes, they must be marked by dots (no larger than 1/4) or equivalent for easy identification. Dots must be able to be seen from floor level. f. All light switches that control lighting in lobbies or open work area are to be ganged together in the adjacent lobbies or open work areas. No light switches are to be located in areas used by the public. g. Hallway lighting controls should be located convenient to the designated employee entrance. h. Loca

Bid Related Documents

Download Document

Product Code: 97145

Agency Information


Issuing Agency: County of San Bernardino

State: California

Agency Type: State and Local

Contact: Contracts Compliance Unit, 351 N Mountain View, 2nd Floor, San Bernardino, California, 92415

< PREVIOUS PAGE

GET A FREE
MARKET
ANALYSIS

FREE Market Analysis


Get a FREE 90-Day Market Analysis and see the bids you’ve been missing

GET BIDS NOW