Government Contract | Texas
HVAC Replacement @ San Angelo DHQ

Bid Information

Bid Alert No: 00000571847

Bid Title: HVAC Replacement @ San Angelo DHQ

Agency Bid No. Title: 07-470401699

Received Date: 05/17/2016

Close Date: 06/08/2016

Purchase Type: 90 days for completion

Delivery Point:

Delivery Date: Not Stated

Special Notices: Pre-Bid Conference Optional 05/24/2016 10:30 AM


Specifications include, but are not limited to:Scope of Work includes but not limited to replacement of eight package units onthe Warehouse/Shop roof and two split systems on the Traffic roof:Shop/Warehouse Building # 078046 (B): Install four 5-ton gas heat RTU460/3PH R410a; install four 20-ton cooling only RTU; install eight digitalprogrammable thermostats (as specified by Owner); install four smoke detectorson the four individual 20-ton RTUs (as specified by Owner); connect into existingelectrical and 24 volts; reconnect gas line; reconnect to existing ductwork; replacedrain lines on these four RTUsTraffic Building # 078093 (D): Install two 4-ton air conditioning system; installtwo 90,000 BTU furnace; install two 4-ton coil; flush out existing refrigeration lines;furnish duct connections with canvas connectors; furnish and install tubinginsulation where needed (if lines are accessible).For all units: Removal and proper disposal of existing equipment; connect intoexisting ductwork and furnish proper connections with canvas connector; furnishand install new drain lines; hail screen, if not factory installed; and, check forproper operations.Provide crane for setting units. Furnish all labor and materials to complete the job.Furnish all permits and inspections, if required; Warranties: 5 years compressor, 1year parts, and 1 year labor.1. Unit shall have scroll compressor2. Install liquid line dryer for system3. Install new filter rack for 1 (split system) and 2 inch filter (package units)4. Clean return air area and seal return plenum and unit to return5. Connect to existing ductwork with proper material such as canvasconnectors and metal to duct sealant, where necessary.6. Any duct tape shall be UL approved with acrylic glue per manufacturer.7. Clean refrigerant lines properly with nitrogen by purging lines.

Product Code: 91450

Agency Information

Issuing Agency: State of Texas - Department of Transportation

State: Texas

Agency Type: State and Local

Contact: Daisy Rodriguez TXDOT San Angelo District, 4502 Knickerbocker Road, San Angelo, Texas, 76904

Phone: 956-712-7412




FREE Market Analysis

Get a FREE 90-Day Market Analysis and see the bids you’ve been missing