City of Valdez Level 1 Generators Load Test & Service

Find Open Contracts in the Architecture and Engineering Industry

Find Contracts Now

Bid Information

Bid Alert No: 00000471504

Bid Title: City of Valdez Level 1 Generators Load Test & Service

Agency Bid No. Title: Not Stated

Received Date: 01/29/2016

Close Date: 03/04/2016

Purchase Type: completed by December 1, 2016

Delivery Point:

Delivery Date: Not Stated


Specifications include, but are not limited to:This project includes, but is not necessarily limited to: Provide annual service and load test for all Level #1 Generators owned by the City of Valdez. The service should adhere at a minimum to NFPA 110. At a minimum (Courtesy Cummins Northwest Maintenance Check List): 1.Engine Oil - Check for leaks, oil level and pressure, full flow and bypass oil filters, change oil and oil filters, take oil sample, check hydraulic/mechanical governor oil level. 2.Engine Cooling Check for leaks, radiator air restriction, radiator duct work and fan shroud,fan hub, drive pulley, belt tension/condition, water pump, coolant level and antifreeze point, DCA level, coolant condition, coolant heater operation, hose condition and connections, coolant filter, radiator cap, motor or mechanical louver operation. 3.Engine Air Intake System Check for leaks, air cleaner restriction, clean or replace air cleaner and housing, all air intake piping, clean crankcase breather element. 4.Engine Fuel System Check for leaks, fuel lines and connections, governor control linkages, fuel transfer pump for leaks and operation, drain sediment from day tank, day tank fuel level, main tank fuel level, water contamination in day or main fuel tanks, change fuel filter, change or clean day tank supply filter, change water separator filter. 5.Engine Exhaust System Check for exhaust leaks, drain exhaust condensation trap, check rain cap. 6. Engine Electrical System Check alternator and battery charge rate, battery connections and terminals, battery electrolyte levels, battery specific gravity, engine safety controls/alarms/wiring. 7. Engine Related Components Check vibration and metal cracks, engine mounting hardware and tighten, dirt/debris and clean blow-by vents, grease fan pillow block bearing. 8. Main Generator Check air inlet and outlet restrictions, grease generator bearing, perform operational load test with load bank and any other equipment needed to conform testing to Level 1 generators requirements, check output circuit breaker for loose or unsatisfactory load and line lug connections, AC meter readings

Bid Related Documents

Download Document

Bid Related Attachments

Download Attachment Download Attachment

Product Code: 93639

Agency Information

Issuing Agency: City of Valdez

State: Alaska

Agency Type: State and Local

Contact: City of Valdez, Public Works, P.O. Box 307, Valdez, Alaska, 99686



FREE Market Analysis

Get a FREE 90-Day Market Analysis and see the bids you’ve been missing