Government Contract | New York
AIR FILTER SERVICES FOR HEATING, VENTILATION, AND AIR CONDITIONING (HVAC) SYSTEMS AT THE PORT AUTHORITY BUS TERMINAL (PABT)

Bid Information


Bid Alert No: 00000488078

Bid Title: AIR FILTER SERVICES FOR HEATING, VENTILATION, AND AIR CONDITIONING (HVAC) SYSTEMS AT THE PORT AUTHORITY BUS TERMINAL (PABT)

Agency Bid No. Title: 45143

Received Date: 02/16/2016

Close Date: 02/25/2016

Purchase Type: Term:

Delivery Point: Various Locations - NY & NJ

Delivery Date: Not Stated

Special Notices: Bidder Preregistration, Warranty Required

Specifications

Specifications include, but are not limited to:A. Disposable Filter-Extended Surface1.Filters shall be Underwriters Laboratory ( UL) Class 1. All pleated filtersshall be of a minimum of MERV 8. Charcoal Pleated filters shall be aminimum of MERV 8, Cell filters shall be a minimum of MERV 14.2.The UL Class 1 Filters manufactured by Viskon-Aire Corporation or a PortAuthority approved equal may be used in lieu of the aforementionedextended surface type unless otherwise directed by the Manager.B. RollFilterRoll filter shall be UL Class 1 as manufactured by American Air Filter Corporation,Viskon-Aire Corporation or a Port Authority approved equal. All materials for ULClass 1 roll filters, including filter media, shall be UL Class 1. Rated media facevelocity shall be 500 fpm. The initial resistance of the clean media at 500 fpm shallnot exceed 0.15w.g. The average arrestance shall be at least 70 %. The filters willbe run to a final resistance of 0.50w.g. The filtering media shall be 65 feet long andshall be rolled and installed in a manner to permit the proper operation of theexisting feed mechanisms without alteration. Media shall be 2 fiberglass. Mediamust have sufficient strength to maintain its full width under the tension created asthe roll advance.C. Absolute Filters 99.97% EfficiencyFilters shall be Absolute Filters, or Port Authority approved equal. They shall beindividually tested and certified to have an efficiency of not less than 99.97% whentested with 0.3 micron dioctylphthalate smoke (DOP TEST). The clean filter staticpressure drop shall be no greater than 1w.g. when operating at rated capacity of1000 cfm, and shall be able to reach 2w .g. without unloading or collapsing. Filtershall be supplied with one Neoprene gasket and shall be leak proof when installed inhousing. Filter frame shall be galvanized steel.D. Type FG-Disposable FiltersThick throw-away to 1 filter (type FG) shall be flat glass wool blanket type,held in a snap-in metal frame, or throw-away cardboard frame similar to existingfilters. Only Farr, Continental, or American Air Filter disposable filters may beused as replacement filters or a Port Authority approved equal is obtained tosubstitute and is UL Class 1.

Product Codes: 91036, 99247

Agency Information


Issuing Agency: Port Authority of New York and New Jersey

State: New York

Agency Type: State and Local

Contact: Luz Santana, Procurement Department 4 World Trade Center, 150 Greenwich Street, 21st Floor, New York, New York, 10007

Phone: 212-435-3949

Fax: 212-435-3959

Email: lsantana@panynj.gov