Government Contract | California
3 Phase TTR with Printer

Find Open Contracts in the Architecture and Engineering Industry

Find Contracts Now

Bid Information


Bid Alert No: 00000941397

Bid Title: 3 Phase TTR with Printer

Agency Bid No. Title: 89127

Received Date: 04/27/2017

Close Date: 05/03/2017

Purchase Type: 60 days

Delivery Point: 1630 N. Main Street, Los Angeles, California, 90012

Delivery Date: Not Stated

Special Notices: Questions Due By 05/01/2017 02:00 PM

Specifications

Specifications include, but are not limited to: 3EACHNAICS: 3345153-Phase Transformer Turns Ratio Tester with PrinterFeatures:-The ability to store up to 128 transformer Test Plans. A Test Plan need to consist of the nameplate voltage for each tap, the calculated ratio based on the nameplate voltages, the measured turns ratio for each tap with the percent error and Pass/Fail results.-The ability to create a test plan with PC software and then transferred to the test unit by RS-232C port, USB port, and USB Flash drive port interfaces.-Load Tap Changer tap positions can be changed remotely from a built-in LTC Control Interface.-Built-in 4-1/2" wide thermal printer.-USB Flash Drive Interface for transferring up to 999 Test Plans and test records to or from a USB Flash Drive.-Single H test lead connector and single X test lead connector on the test set to prevent the H leads and the X leads from being connected incorrectly at the test set.-The H test lead set shall be a one cable set consisting of 4 leads for 3-phase connections and 2 leads for single phase connections with large clamps on each lead.-The X test lead set shall be a one cable set consisting of 4 leads for 3-phase connections and 2 leads for single phase connections with large clamps on each lead.-Test lead extension sets shall be one cable for with 4 leads for the 3-phase set and 2 leads for the single phase set.-Test unit that can automatically detect 130 specific vector groups from different transformer types defined by ANSI, CEI/IEC, and Australian standards.-Test unit that can automatically display suggested test lead connections on the transformer if it detects an incorrect connection.Specifications:-Input Power: 100-240Vac, 60 Hz.-ITC Contact: 240Vac, 2A.-Cables: 15ft single phase set one for H and one for X, 15ft 3-phase set one for H and one for X, 25ft extension set one for H and one for X. one safety ground, one RS-232C, one USB, and cable bag. -Measuring Method: ANSI/IEEE C57.12.90.-Ratio Measurement Range: 0.5-15,000:1.-Test Voltages: 8Vac @ 1.0 A, 40Vac @ 0.2 A, 100Vac @ 0.1 A.-Accuracy: 8Vac: 0.08% @ Ratio(0.8-1000), 0.1% @ Ratio(1001-4000), 0.25% @ Ratio(4001-15000). 40Vac: 0.05% @ Ratio(0.8-1000), 0.1% @ Ratio(1001-4000), 0.2% @ Ratio(4001-15000). 40Vac: 0.05% @ Ratio(0.8-1000), 0.1% @ Ratio(1001-4000), 0.2% @ Ratio(4001-15000).-Current Reading Range: 0-1Amps, accuracy 0.1mA, 2% of reading (1mA).-Phase Angle Measurement: 0-360 degrees, accuracy 0.2 degrees (1 digit).-Display: Back-lit LCD screen (128x64 pixels) viewable in bright sunlight and low-light levels. Test screen displays the transformer turns-ratio, excitation current, phase angle, and percentage error.-Keypad: Data input by a rugged 16-key, membrane keypad and a digital rotary switch.-Printer: 4 1/2" wide thermal printer.-Computer Interfaces: RS-232C port and USB port.-External Data Storage: Up to 999 Test Records on external USB flash drive.-Internal Test Record Storage: Stores 112 complete transformer test records, each record holding the test record header and up to 99 readings.-Internal Test Plan Storage: Stores up to 128 transformer test plans that can transferred to a PC.-PC Software: Windows based transformer turns-ratio analysis software.-Safety: designed to meet IEC(1995), UL 61010A-1, and CSA-C22.2 standard.-Environment: Operating: (15F to 122F), Storage: (22F to 158F), Humidity: 90% RH @ 104F. Altitude: 6,562ft full operation.-Dimensions: 18"W x 7"H x 15"D.-Weight: 20lbs.-Warranty: One year parts and labor."VANGUARD" ATRT-03 S2

Bid Related Documents

Download Solicitation Notice

Product Code: 28780

Agency Information


Issuing Agency: Los Angeles Department of Water and Power

State: California

Agency Type: State and Local

Contact: Martin Herrera 1630 N. Main Street, Los Angeles, California, 90012

Phone: 213-367-2537

Email: martin.herrera@ladwp.com