Government Contract | New York
2017 Generator Service for Nassau and Suffolk Counties

Find Open Contracts in the Architecture and Engineering Industry

Find Contracts Now

Bid Information


Bid Alert No: 00001076307

Bid Title: 2017 Generator Service for Nassau and Suffolk Counties

Agency Bid No. Title: LI 082517

Received Date: 09/01/2017

Close Date: 09/04/2017

Purchase Type: Not Stated

Delivery Point: Not Stated, New York

Delivery Date: Not Stated

Special Notices: Questions Due By Optional 09/21/2017

Specifications

Specifications include, but are not limited to: 1. Change Engine Oil, and oil filteroil filter shall be dated with magic marker on installation.Old engineoil/filter must be disposed of properly, list same on report.2.Test engine protective and automatic shutdown devices, where applicable, low oil pressure, low coolantlevel, high coolant temperature, overspeed, etc. and any and all other safety devices the equipment may beequipped with.List findings on report.3. Test Battery and log charging voltage, where applicable.Check and inspect battery cables andposts.Keep battery posts and cable clamps clean and tight.Check for proper electrolyte level in batterycells where applicable, add distilled water when necessary.NEVER use tap water.Inform Work Controlat 516.576.5031 if the battery is required to be replaced.Authorization to proceed may be given at thattime.4. Perform operational test under load conditions (minimum run time 30 minutes) take amperage readingseach leg, log same on report.5. Inspect transfer switch and all electrical connections for proper operation and condition, log findings onreport.6. Check/clean or replace air filter.7. Check/adjust vbelt for alignment and tension where applicable.Tension is correct when a force of about20lbs, applied between pulleys, causes a belt deflection of 1/4 to 1/2 inch.Check all cooling system hosesfor condition, change any hoses that require replacement as necessary, and log on report.8. Check block heater for proper operation, where applicable.9. Clean/wipe down all generator housings/enclosures.Report any oil/antifreeze leaks, whereapplicable.Correct those deficiencies wherever possible.10. Check all fuel/exhaust plumbing for leaks, correct where necessary.11. Check all fluid levels including oil, antifreeze, and battery.Top off as necessary12. Adjust frequency (Hertz) to correct noload setting according to manufacturers recommendations.13. Check noload voltage, adjust voltage regulator if necessary.14. Replace fuel filter/bleed the fuel system where applicable.

Product Code: 93639

Agency Information


Issuing Agency: State of New York-Office for People With Developmental Disabilities

State: New York

Agency Type: State and Local

Contact: Michael Detz Taconic Developmental Disabilities Services Office, 26 Center Circle, Wassaic, New York, 12592

Phone: 845-877-6821

Fax: 845-877-3004

Email: michael.x.detz@opwdd.ny.gov

< PREVIOUS PAGE

GET A FREE
MARKET
ANALYSIS

FREE Market Analysis


Get a FREE 90-Day Market Analysis and see the bids you’ve been missing

GET BIDS NOW